This store requires javascript to be enabled for some features to work correctly.

ORDER BEFORE 1PM MON-FRI FOR SAME DAY DISPATCH

GET UP TO 15% OFF IN OUR BLACK NOVEMBER SALE

10% off RRP tiles when you spend up to £1000
15% off RRP tiles when you spend over £1000
Offer ends Midnight 30th November 2024
Discount applied at checkout
Sale

Schluter Ditra Matting Peel and Stick

D000071
  • £0.00
  •  
  • £18.56
VAT included. Shipping calculated at checkout.

1: Select Product Option

Size

Current Stock
Delivery Time 2-5 working days
shipping method dependant
Need more?
dependant on availability

2. Calculate Quantity


Add 10% for Cutting & Wastage?
This will round up to the nearest box or tile

Our goal is to deliver all orders within the estimated lead time provided at checkout, which is typically 2-3 business days. Please keep in mind that lead times are in business days and do not include weekends or holidays. We will send you tracking details or information about the expected delivery date of your order via email as soon as it has been processed. If the items you ordered are out of stock or are special order items that are being imported for you, we will communicate with you about the expected lead time and provide an estimated delivery date once your order has been dispatched from our warehouse or our supplier. Please note that we can only give an estimated delivery date and cannot guarantee an exact arrival date.

We have a 30-day return policy, which means you have 30 days after receiving your item to request a return.

Returns within 30 days of delivery of our own materials correctly supplied are subject a handling charge of 25% plus any repatriation carriage charges

Returns within 30 days of delivery of special-order items correctly supplied are subject to the supplier's terms and conditions, which may incur up to a 35% handling charge plus any repatriation carriage charges.

To be eligible for a return, your item must be in the same condition that you received it, in its original packaging. You’ll also need the receipt or proof of purchase.

To start a return, you can contact us at fulham@europeanheritage.co.uk. Please note that returns will need to be returned to one of our physical locations.

If your return is accepted, instructions on how and where to send your package will be provided. Items sent back to us without first requesting a return will not be accepted.

Yes, we do ship to Northern Ireland. For parcels shipped via ParcelForce, we will need no additional information from you.

For palletised heavy haulage, there is a short process that you will need to go through to obtain your EORI number, allowing us to complete the necessary customs requirements for you.

You will first need to apply for a GB EORI number by using your National Insurance Number, and convert this to an XI EORI number specifically for Northern Ireland. This can all be done through the government portal. https://www.gov.uk/eori/apply-for-eori

We will need your XI EORI number before we despatch your order.

If your order is for an in-stock item, you can choose to have it collected from one of our showrooms at checkout. If your order is for a special order item, it can be delivered directly to you or to one of our showrooms if you prefer to have us handle the receipt of the goods.

We welcome all major debit and credit cards, such as Visa, Mastercard, and American Express. You can find a comprehensive list at the bottom of our website. Additionally, we offer convenient payment options like Apple Pay, Google Pay, and Shop Pay for faster transactions during checkout.

For security reasons, it's essential that the billing address associated with your card matches the one provided at checkout. If there is a discrepancy between the billing address on your card and the one you entered, your transaction may not be authorised and the payment will fail.

In such cases, your bank may hold the funds as a 'pending transaction', but some may show them as a regular transaction. How long the transactions are held for depends on your bank. Typically these transactions are reversed within 24 hours, but may take up to 5 working days.

If you reattempt checkout with the correct billing details, you won't be charged again, but your transaction will be authorised and your order will processed.

Our commitment to preventing fraud and ensuring the safety of our business and customers leads us to employ an extra layer of security for online credit and debit card transactions. All successfully authorised payments undergo authentication using 3D Secure. It's important to note that your credit card number is neither stored nor accessible during or after the processing of your order, enhancing the security of your transactions.

Product Description

Schlüter-DITRA-PS is a polypropylene mat with EasyCut gridlines as well as undercut, square EasyFill recesses and an anchoring fleece and pressure sensitive adhesive laminated to the underside.

It is a universal substrate for tile coverings, which forms an uncoupling and vapour pressure equalisation layer.

DITRA-PS is exclusively intended for installation on floors in interior areas. Substrates for installing the product must be level, clean, dust free, dry, smooth, rigid and load bearing, with no deflection. To install, peel the release film off DITRA-PS and place the mat on the substrate. It can be lifted and re-positioned providing no pressure has been applied to it. However once pressure has been applied the adhesive sticks the membrane firmly to the substrate.

Tiles can be installed in accordance with the applicable regulations immediately after adhering the mat, using the thin-bed method.

Summary of functions

a) Uncoupling

Schlüter-DITRA-PS uncouples the covering from the substrate and neutralises tensions between the substrate and the tile covering that result from various deformations. The material also bridge tension cracks from the substrate and prevent them from affecting the tile covering.

b) Waterproofing

DITRA-PS is waterproof and suitable for use in wet areas, provided the abutting joints are sealed with Schlüter-KERDI-KEBA and Schlüter-KERDI-COLL-L.
Note: DITRA-PS has no ETA or abP certification. If ETA or abP certification is required, we recommend using the original Schlüter-DITRA which is bonded to the substrate with thin-bed mortar.

c) Vapour pressure equalisation

The air channels of DITRA-PS remain open on the underside and so allow vapour pressure equalisation in the event of moisture exposure from behind.

d) Load distribution (load induction)

Tiles installed over DITRA-PS in floor areas should have a minimum size of 5  x  5  cm and a thickness of at least 5.5  mm.

The mortar-filled, square recesses of DITRA-PS transfer mechanical stresses impacting the tile covering directly to the substrate. This makes tile coverings installed on DITRA-PS especially durable. Where traffic loads are high (e.g. in commercial areas) or high point loads are expected (such as concert grand pianos, forklift trucks or shelf systems, etc.), the tiles for each area must be sufficiently thick and have adequate compressive stability. The information and tile thicknesses specified in the ZDB information sheet "Ceramic floor coverings with high mechanical stress resistance", valid in Germany, must be observed.

Tiles in high-stress areas must be wholly embedded in the tile adhesive. The impact of hard objects should be avoided on ceramic coverings.

e) Adhesive bond

The special adhesive layer on the underside anchoring fleece of DITRA-PS sticks well to the substrate, while the mechanical anchoring of the thin-bed mortar in the under-cut square indentations results in an excellent bond with the tile covering.

 

How to install this product

  1. The substrate must be free of anything that could inhibit adhesion, level and load-bearing. Any necessary levelling work must be completed before installing DITRA-PS.
  2. The substrate must be dust-free before installation and must therefore be thoroughly vacuumed.
    Note: Although it is not mandatory to apply a primer, a standard primer without coarse components such as quartz sand may be used if the condition of the substrate necessitates it.
  3. Cut the uncoupling mat DITRA-PS to size and lay it out on the floor. Now remove the release film from the fleece on the underside and press the mat evenly on the substrate, using a float or roller. It is helpful to align the DITRA-PS accurately as soon as it is laid and to lay it under a slight tension.
  4. To prevent damage to the laid DITRA-PS or its becoming detached from the substrate, we recommend that you protect the area from mechanical stresses, e.g. by laying out running boards (particularly in areas used for transport of materials).
  5. Immediately after fitting the DITRA-PS, tiles can be installed using the thin-bed method, using a thin-bed mortar appropriate to the requirements of the covering. The notch size of the trowel must suit the tile format. Observe the curing time of the thin-bed mortar. The tiles should mostly be fully embedded in the mortar. Full contact according to the applicable professional regulations is especially relevant for coverings exposed to high mechanical stresses.
    Note: The square indentations can be filled using the smooth side of the notched trowel (mortar requirement approx. 2.0 kg/m²) and the thin-bed mortar can then directly be grooved with the (correctly sized) notch, in a single work step. Depending on the tile size or the site conditions, it may alternatively be more effective to first fill the indentation with the tile adhesive used for the installation. Tile installation can begin once the trowelled surface is firm enough to walk on. Note that the substrate must be free of dust prior to installation. If necessary, vacuum the substrate prior to installation or apply a primer in case of doubt.
    Any potential material incompatibilities should be checked beforehand. If using covering materials with a side length exceeding 30 cm, we recommend a fast-setting tile adhesive with crystalline water binding to facilitate the rapid strength development and drying of the mortar.
  6. Follow the instructions in the data sheet and the other technical regulations when installing movement joints for perimeter, edge or connection joints.

Waterproofing with Schlüter-DITRA-PS

Unless a certified bonded waterproofing assembly is required, DITRA-PS can serve as a waterproofing layer, provided the abutting membrane seams and the connections to installed components and upright building structures are carefully sealed.

If national technical approval (abP) or European approval (ETA = European Technical Assessment) is needed, choose the DITRA variants for installation with thin-bed mortars that have the corresponding certification.

DITRA-PS protects the substrate from damage caused by permeating moisture and aggressive substances. For sealing joints, trowel the sealing adhesive Schlüter-KERDI-COLL-L over the abutting joints and embed the sealing band Schlüter-KERDI-KEBA in a minimum width of 12.5 cm over the joints.

To waterproof floor-wall transitions, adhere KERDI-KEBA over DITRA-PS on the floor and directly on the substrate in wall areas in the corresponding width. The sealing tape must have an overlap of at least 5 cm. KERDI-KEBA can also be used to create functional connections to fixed structural components such as door and window frames made of metal, wood or plastic. The first step is to apply Schlüter-KERDI-FIX to the adhesive surfaces of the structural elements. The remaining width is then fully adhered to DITRA-PS with KERDI-COLL-L.

The suitability of KERDI-FIX for the materials of the structural components must be verified in advance. Separate DITRA-PS at existing movement joints or structural movement joints and seal the abutting joints with Schlüter-KERDI-FLEX.

KERDI-FLEX should also be used for flexible edge finishes. KERDI-KEBA can also be used here as an alternative, by forming an appropriate loop.

Substrates for Schlüter-DITRA-PS

The substrates on which DITRA-PS is to be installed must be thoroughly checked for suitability, e.g. that they are level, load-bearing, clean and compatible with the materials used. Remove any surface components that could weaken the bond. Any levelling, height adjustment or slope compensation must be carried out before DITRA-PS is laid.

Concrete

Concrete is prone to long-term structural deformation due to shrinkage. In addition, deflection in concrete and pre-stressed concrete can cause tensions to occur.
Since DITRA-PS absorbs the resulting stresses between the concrete and the tile covering on the floor, tiles can be immediately installed as soon as the concrete is ready to bear weight.

Cement screeds

Cement screeds must have cured for at least 28 days prior to tile installation in accordance with the applicable regulations and have a moisture content below 2 CM %. Floating and heated screeds have a particular tendency to buckle and crack even later, e.g. due to mechanical stresses and temperature fluctuations. With DITRA-PS, tiles can be installed on fresh cement screeds as soon as their surface is sufficiently dry (typically this takes approx. 3-5 days for well-ventilated standard cement screeds). DITRA-PS neutralises cracks and screed deformations that occur later and prevents them from affecting the tile covering.

Gypsum based screeds

Under the applicable regulations, calcium sulphate (anhydrite) screeds may have a maximum residual moisture level of 0.5 CM% at the time of tile laying. In contrast, tile installation is permissible from a residual moisture level of 2 CM % with DITRA-PS. If necessary, the screed surface should be treated (grinding, priming) as specified by the technical regulations and manufacturer instructions. DITRA-PS can then be affixed to the pre-treated screed surface. DITRA-PS protects the screed surface against permeating moisture. Because gypsum based screeds are susceptible to moisture, screeds must be protected against humidity, e.g. moisture seepage on the underside.

Heated screeds

DITRA-PS can be used on heated screeds, provided that the notes given above (on cement and calcium sulphate) are observed. Covering assemblies created with DITRA-PS are ready for heating only 7  days after completion. Starting from a temperature of 25 degrees C, the supply temperature can be increased by no more than 5 degrees C a day to a maximum of 40 degrees C. The air channels formed by the DITRA-PS mat allow rapid and even heat distribution under the tile covering.

Note: For floor heating systems, we recommend our Schlüter-BEKOTEC-THERM system as a ceramic thermal comfort floor. DITRA-PS is also highly suitable for uncoupling in conjunction with floor heating systems based on thin electric heating mats. In those cases, Schlüter-DITRA-PS can be installed above or below the heating mat. However, a better uncoupling effect is obtained by placing it above the heating mat. Schlüter-DITRA-HEAT/HEAT-PS was developed specifically as an uncoupling mat designed to attach the matching system heating cables for electric floor/wall heating systems. You can find further details in product data sheets 6.4 and 6.5.

Dry screeds

When fitting DITRA-PS, once dry screed elements have been correctly installed according to manufacturer instructions, you can choose the maximum tile format in any size.

Vinyl coverings and coatings

All surfaces must be load bearing and pre-treated or suitable for bonding with the adhesive anchoring fleece on the underside of DITRA-PS. The compatibility of the adhesive with the substrate must be verified in advance. DITRA-PS may only be installed on substrates that are free of solvents, plasticisers and oils.

Chipboard and compressed wood panels

These materials are prone to particularly severe deformation under the influence of moisture (or fluctuations in air humidity). It is therefore recommended to use chipboard and compressed wood panels with special water-repellent treatment to protect against moisture. However, they have to be thick enough to be sufficiently stable in conjunction with a suitable support assembly. They should be secured with screws placed suitably close together. Joints should be of a tongue-and-groove type and must be bonded with adhesive. Edge joints of about 10 mm should be maintained to adjacent structural elements. DITRA-PS neutralises any tensions with the tile covering and also prevents permeating moisture.

Hardwood floors

In principle, ceramic coverings can be installed on sufficiently weight bearing hardwood floors with tongue and groove connections. The wooden substrate should have balanced moisture levels before DITRA-PS can be installed. It has proven beneficial here to lay an additional layer of chipboard or compressed wood panels. Uneven floor surfaces should be levelled with suitable measures beforehand.


FAQs: Schluter Ditra Matting Peel and Stick

What our customers say!

  • "Lovely tiles. Great selection and excellent quality and all delivered on time in superb condition."

    Anni - GB

  • "Staff were really helpful and informative, especially as I had no idea what I was talking about! We're very clear on additional items needed and what they supply, even down to colour matching grout with tiles etc"

    C. Riggs - GB

  • "It was quick easy to place the order and the goods arrived on time as was stated at time of order"

    Ray - GB

  • "Excellent service via phone, in person. Caroline was very helpful as were the staff when I picked up the tiles this morning."

    Paul - GB